Technical Specifications (TDS)

Dechro-L
Code: 003

Liquid dechroming stabilizer and bath additive formulation.

Dechro-L Technical Data Sheet

Liquid dechroming stabilizer and bath additive formulation.

Operational Specifications

Formulation settings and operational parameters for Dechro-L liquid stripping.

ParameterSpecification Setting
Immersion Target30% - 50% cylinder width
Rotation Speed25 - 75 m/min (Optimal: 50 m/min)
Bath Temperature20°C - 35°C (Optimal: 25°C)
Voltage RatingApprox. 8 V
Current DensityUp to 10 A/dm²
Anodic Removing TimeApprox. 30 - 60 seconds
Cathodic ActivationApprox. 30 seconds
Average Stripping Rate6 to 9 minutes for standard 10 Micron hard chrome layers
Electrolyte Density25° Baume or Dechro ready-to-use solution