Additive values of consumption for hard sulphate copper plating bath.
Cupro Hard Powder Technical Data Sheet
Additive Values & Control Guidelines
The consumption values are dynamic and depend on the chosen hardness. For standard operations aiming for a hardness of 175 - 230 Vickers, the following values apply:
| Operating Parameter | Specification Value / Standard |
|---|---|
| Bolster Up Additive | 200 - 250 ml per 1000 AH (Ampere Hours) |
| Preparation Rule | 40 g dry powder mix in 10 Litres DM (De-mineralized) water |
| Bath Operating Temp | 25°C to 40°C |
| Current Density | 20 - 40 Amp/dm² |
Operational Note: Operational Note: Consumption values fluctuate based on the specific bath temperature and cylinder immersion levels. Regular, continuous dosing is highly recommended.